Options
& Accessories
|
Model TS25T
Outlet Price $15,900
with Trailer
Model TS25S
Outlet Price $14,900
FREE”
Generator Express
Shipping
|
| |
Model
|
TS25T/S
|
|
Engine |
Isuzu |
|
Standby Output - 150'C Rise |
(KVA/kW) |
|
3 ph @ 480 Volt |
25/20 |
|
3 ph @ 208 or 240 Volt |
25/20 |
|
1 ph @ 240 Volt |
18/18 |
|
Prime Output - 125'C Rise |
(KVA/kW) |
|
3 ph @ 480 Volt |
23/18 |
|
3 ph @ 208 or 240 Volt |
23/18 |
|
1 ph @ 240 Volt |
18/18 |
Voltage Selections
|
|
Voltage - 3 ph Adjustable |
208/220/240 416/440/460/480 |
|
Voltage - 1 ph Adjustable |
120/127/139 240/254/277 |
|
3 Phase Power Factor |
0.8 |
|
Voltage Regulation |
1/2% |
|
Frequency (50Hz Available) |
60 Hz |
|
Total Harmonic Distortion |
<5% |
|
Insulation Material |
Class H |
Amperage (Continuous)
|
|
3 ph 480 Volt |
27.1 |
|
3 ph 208 Volt |
62.5 |
|
3 ph 240 Volt |
54.1 |
|
Single phase amperage @240V/120V |
75.0/150.0 |
Engine Specifications
|
|
Model |
4LE |
|
Cylinders |
4 |
|
Induction System |
Nat Aspirated |
|
Displacement, Liter/Cu.In. |
2.2/133 |
|
Hp @ Rated Speed |
34.5 |
|
RPM |
1800 |
|
Bore and Stroke 3.4 x 4.1 |
3.34" x 3.78" |
|
Oil Capacity (with filter) |
8.6 quarts |
|
Cooling |
Liquid |
Battery, Rack and Cable Supplied
|
|
Batter Minimum Cold Cranking Amps |
750 |
Receptacle Specifications
|
|
120 volt 20 Amp Duplex GFCI |
2 |
|
120/240 Volt 50 Amp CS6369 Twistlock |
2 |
|
Two Wire Remote Start Capability |
std |
Fuel System Specifications (Diesel)
|
|
Fuel consumption GPH - 1/2 load/(full load) |
1.3/(2.0) |
|
Approximate Run Time ( Hours) 1/2 load/(full load) |
38/(25) |
|
Fuel Capacity (Gallon) |
50 |
Capacity and Dimensions
|
|
Sound Level dBA @ 7 meters, full load |
64 |
|
Dimensions (LxWxH) with trailer |
131"x62"x72" |
|
Dimensions (LxWxH) without trailer |
74"x38"x52" |
|
Weight with Fuel (lbs.) |
2265 |
|
Weight without Fuel and without Trailer (lbs.) |
1790 |
|
Ratings:
-
Standby
Ratings:
Standby ratings
are
applicable
for
supplying
emergency power
for the
duration
of a
utility
power outage.
Primary power to
the
installation is
utility
supplied. No
overload
capability for
standby
rating. Standby
ratings
in accordance
with ISO
3046,
BS55114,
DIN
6271.
Continuous
Power
Rating:
Continuous
power is
the
maximum power
available
for
continuous duty.
A 10%
overload
capacity
is
available
for
1
hour
out
of
12
hours
of
operation.
For
additional
information,
please
consult
factory.
Manufacturer
reserves
the
right
to
implement
specifications
or
design
changes
without
notice.
WARNING:
Do
not
connect
generator
to
any
building’s
electrical
system
unless
a
disconnect
switch
has
been
installed. |