Automatic Transfer Switches (ATS)


Cutler-Hammer Switch
240 Volt - 2 Pole
200 Amp - 800 Amp
 

2 Pole Contactor ATS with 300 Series Controller (800 Amp-Molded Case)

2 pole Contactor ATS w/ 300 Series Controller
( 800 AMP-Molded Case)
RATING CATALOG NUMBER Price(F.O.B. Factory)
200/2 N1 ATC3C2X20200WSU $1,495
200/2 N3R ATC3C2X20200WRU $1,595
320/2 N1 ATC3C2X20320WSU $1,895
320/2 N3R ATC3C2X20320WRU $1,995
400/2 N1 ATC3C2X20400WSU $2,195
400/2 N3R ATC3C2X20400WRU $2,295
600/2 N1 ATC3C2X20600WSU $3,695
600/2 N3R ATC3C2X20600WRU $3,795
800/2 N1 ATV3MDA20800WSU $3,895
800/2 N3R ATV3MDA20800WRU $4,195

2 Pole Molded Case ATS Service Entrance Rated with 300 Series Controller

2 Pole Molded Case ATS SERVICE ENTRANCE RATED w/ 300 Series Controller
RATING CATALOG NUMBER Price
F.O.B. Factory
225/2 SE 3R ATH3FDC20225WRU $2,795
300/2 SE 3R ATV3KDC20300WRU $3,295
400/2 SE 3R ATV3LDC20400WRU $3,795
600/2 SE 3R ATV3MDC20600WRU $5,695
800/2 SE 3R ATV3NBC20800WRU $5,995

2 Pole ATS with Distribution Breakers

2 Pole ATS
w/ Distribution Breakers
RATING / POLES CATALOG NUMBER # 200 AMP DISTRIBUTION BREAKERS Price
F.O.B. Factory
200/2 N3R ATV3KDC20200WRU 2 $3,395
300/2 N3R ATV3KDC20300WRU 2 $3,995
400/2 N3R ATV3KDC20400WRU 4 $5,195
600/2 N3R ATV3KDC20600WRU 4 $6,395

General Description of ATS

Catalog Number AT-3C2X20---XSU 1, 2, 3, 4, 5h, 5j, 5k, 5l, 6b, 7, 8c, 8d, 12c, 12d, 12g, 12h, 14g, 14h, 23k, 26d, 26h, 26j, 26k, 32f, 35a, 42

Open Transition

240/120 V

60hz 2 Phase

3 Wire

Enclosure Type Type-3R

Continuous Current ----- Amps

ATS Logic Instruction

Test.PDF

AT--3C2 3

1. Time Delay Normal to Emergency

2. Time Delay Engine Start

3. Time Delay Emergency to Normal

4. Time Delay Engine Cool-off

5h. Source 2 ALL Phase Rotation Protection

5j. Source 2 All Phase Undervoltage/Underfrequency Protection

5k. Source 2 All Phase Overvoltage/Overfrequency Protection

5l. Source 2 Three Phase Voltage Unbalance/Loss

6b. Test Pushbutton

7. Time Delay Engine Fail

8c. Time Delay Bypass Emergency to Normal

8d. Time Delay Bypass Normal to Emergency

12c. Pilot Light Normal Position

12d. Pilot Light Emergency Position

12g. Pilot Light Normal Source Available

12h. Pilot Light Emergency Source Available

14g. Normal (S1) Source Present 2NO/2NC

14h. Emergency (S2) Source Present 2NO/2NC

23k. Auto Plant Exerciser 1/7/14/28 Day

26d. Go To Source 2

26h. Source 1 All Phase Rotation Protection

26j. Source 1 All Phase Undervoltage/Underfrequency Protection

26k. Source 1 All Phase Overvoltage/Overfrequency Protection

32f. In-Phase Monitor

35a. Pre-Transfer Signal Contacts 1NO/1NC

42. Seismic Zone 4 Qualified (BOCA,CBC,IBC,UBC